TM 5-1260-206-12
APPS Assembly Procedures - Continued
Table 2-2.
STEP ITEM
NO.
PROCEDURE
Prism holder (9) - Remove from case 5.
12
Through bolts (2 each) (10) - Remove from case 5.
a. Mount prism holder on mirror tubes.
b. Insert one through bolt into each hole in prism holder.
c. Tighten both bolts at same time to prevent binding.
Mounting plate assembly (11) - Remove from case 5.
13
a.
Turn eyebase adjust (12) to mid range.
Position plate assembly on top of prism holder and tighten
b.
screw (13).
Monocular (fixed eyepieces installed) (2 each) (14) - Remove from case 5.
14
Zoom eyepieces (2 each) (15) - Remove from c a s e 5 (if desired).
If zoom eyepieces are desired,
a.
i n s t a l l in monocular.
Without rotating monocular,
b.
insert them into mounting plate
assembly (11) until firmly
seated.
Tighten two knurled screws (16).
c.
2-29