ARMY TM 5-6675-308-34
MARINE CORPS TM 08837A-34/2
To prevent damage, do not move PADS for
at least 2 minutes following shutdown.
a. Turn on +28V power source.
b. Power is applied to PADS by setting PS BATTERY
and VEHICLE circuit breakers CB1 and CB2 to
ON. Activate the system by pressing CDU
ON/OFF. The display cues for spheroid for core
memory, or GPS C-E for solid state memory.
If PADS is on, pressing ON/OFF initiates shut-
c.
down. Systems with a core memory cue OFF C-E
on the CDU display. To turn off press ENT Sys-
tems with a solid state memory first cue SAVE C-E.
If a save of mission data or a spheriod 200 series
alignment (Z gyro bias) align next data is desired,
ENT should be pressed (recommended at all
times). The CDU display will indicate SAVE for 15
to 20 seconds then cue "OFF" -E. At this time OFF
is pressed then ENT The system will shut down.
In the event that the operator elects to continue sys-
tem operation he should press CLR when cued
with OFF C-E (core memory), or CLR when cued
with SAVE C-E, then when cued with OFF C-E, he
should press OFF then CLR. The system will revert
to the last display and continue operation.
d If the operator continues with the OFF mode, set
PS BATTERY and VEHICLE circuit breakers CB1
and CB2 to OFF once the CDU has turned off.
a Dim. Press and hold LAMP to dim CDU lights.
All lamps light and the intensity slowly deereases.
At full dark, no further change will occur. Release
LAMP when desired intensity is reached. The
display returns to previous indication at the new
intensity.
Change 6
3-2.1/(3-2.2 blank)