ARMY TM 5-6675-308-12
MARINE CORPS TM 08837A-12/1A
Table 3-2. Mission Procedures-Continued
Step
CDU data
Status
no.
Operator action
display
indicators
Reference
NOTE
Steps j thru m apply to the solid state
memory only. If, for security reasons, the
operator does not want to store previously
worked data, the following shutdown
sequence should be followed.
j . Press O N / O F F
SAVE C-E
k. Press C L R
"OFF" C-E
l. Press O N / O F F
OFF "C-E"
m . Press E N T
(All displays darken)
n . Turn off PS BATTERY and VEHICLE
circuit breakers CB1 and CB2
Turn off vehicle engine
o.
14.
AFTER-OPERATION CHECKS AND
SERVICES
a. Inspect for excessive accumulation
of dirt and debris. Clean as
necessary.
b . Inspect for damage to primary
pallet, battery box, CDU, and cables
3-35
Change 2