Table 4-6. Computer Diagnostic/Alignment Program - Continued
Malfunction
Test procedure
indication/corrective
action
Normal indication
1k. Turn on + 28V power source
1l. Set PS BATTERY and VEHI-
CLE circuit breakers CB1 and
CB2 to ON
2. CPU TEST
NOTE
If any card assembly is replaced dur-
ing this test, repeat the test from
step 1h.
2 a . Press PADS ON/OFF switch- PADS ON/OFF switch-indicator
P A D S ON/OFF switch-indicator
indicator to on
lights. PARITY ERROR indicator
does not light: Computer power
may light
supply malfunction. Remove and
troubleshoot in accordance with
Defective computer: Measure resis-
IMU FAIL indicator lights. COMP
indicator may light
kilohm scale across computer
thermostatic switch S1. If less
than 500 ohms, disconnect lead
less than 500 ohms, replace ther-
wire harness short between E23
and E50. If shorted, repair or re-
place as required
If resistance is greater than 500
ohms, replace I/O discrete card
A9, then data buffer card A6
E23, XA6-007, and XA9-003. Re-
pair if open
If comma does not oscillate, mea-
Comma in computer time totalizing
sure the voltage across the time
meter M1 oscillates
totalizing meter. If greater than
105 VAC, replace time totalizing
meter. If less than 105 VAC,
check wiring
NOTE
The following step will be an aid in
determining memory unit type if un-
known.