Table 4-20. Computer Power Supply Testing and Troubleshooting
Malfunction
Normal indication
indication/corrective action
Test procedure
Before removing covers or circuit cards, disconnect power from the power supply by
setting COMP PS switch and INPUT POWER UUT circuit breaker to OFF or damage to
equipment may result.
NOTE
AU controls, indicators, switches, switch indicators, and test jacks called out in the
testing and troubleshooting procedure are located on the PSTS, unless otherwise indicated.