ARMY TM 5-6675-308-34
MARINE CORPS TM 08837A-34/2
Table 4-6. Computer Diagnostic/Alignment Program - Continued
Malfunction
Test procedure
Normal indication
indication/corrective action
NOTE
NOTE
Press MEMORY LOAD switch-indi- Ignore PARITY ERROR switch-indi-
cator off and back on if a stop code cator light unless tape stops.
is reached prior to tape data being
read.
MEMORY LOAD switch-indicator
3b. Press MEMORY LOAD switch-
indicator to off
goes off
3c. Press REVERSE switch-indica-
REVERSE switch-indicator lights.
tor to ON
Tape rewinds and stops at begin-
ning of reel
REVERSE switch-indicator goes off
3d. Press REVERSE switch-indica-
tor to off
NOTE
Tape will stop near the beginning of
the reel. Repeat steps 3c and 3d
until tape stops at end of readable
leader.
3e. Set tape reader SPOOLING
switch to DISABLE
3f. Remove part 1 and load part 2
(of 2) of PADS diagnostic align-
ment tape number 877418-5 on
tape reader
3g. Set tape reader SPOOLING
switch to ENABLE
3h. Press MEMORY LOAD switch-
MEMORY LOAD switch-indicator
indicator to on
lights. Tape reader reads next tape
section and stops at end of reel
3i. Press MEMORY LOAD switch-
MEMORY LOAD switch-indicator
indicator to OFF
goes off
3j. Press EXECUTE switch-indica-
EXECUTE switch-indicator lights
tor to on
TTY prints out:
PADS DIAGNOSTIC
ALIGN-
MENT PROGRAM
PROGRAM CHECKSUM XXXXXX
SELECT TEST MODE
4-54
Change 1