C 3, TM 9-1290-335-35
CHAPTER 5
REPAIR AND OVERHAUL
Section I. GENERAL
not be construed as authority to disassemble any
5-1. Scope
segment of the materiel unless the need has first been
a.
This chapter contains detailed instructions
established.
for the repair of the azimuth indicator at direct support
and general support maintenance levels. Depot shops
5-3. Parts Replacement
are authorized by virtue of their facilities and skills to
In subsequent repair paragraphs, replacement of parts
repair or replace all parts listed in Appendix B of this
damaged beyond repair is understood.
manual.
b.
Until further notice the direct and general
support level of repair and maintenance on the azimuth
Refer to TM 9-254.
indicators is limited to the replacement of the
incandescent
lamps
and
complete
indicators.
Decontamination and internal repair and maintenance
5-5. Rescinded.
will be undertaken only by depots specifically designated
by Headquarters, U.S. Army Materiel Command.
5-6. Rescinded.
5-2. Maintenance Technique
These procedures include instructions for complete
disassembly of the materiel. However, instructions will
Section II. REMOVAL OF MAIN ASSEMBLIES
Table 5-1. Main Assemblies and Sequence of Removal
5-7. General
Continued
This section provides instruction for the sequential
disassembly of the azimuth indicator 10954720 into
main assemblies. Table 5-1 lists the main assemblies
References
Step
Description
Identifying
and removal sequence.
number
Fig.
Para
Table 5-1. Main Assemblies and Sequence of Removal
References
2
HOUSING, assembly,
10954707
Step
Description
Identifying
and related parts.
number
Fig.
Para
3
HOUSING, assembly,
10954711
1
HOUSING, assembly,
7537556
and related parts.
and related parts.
Section III. REPAIR AND OVERHAUL OF HOUSING ASSEMBLY
7537556 AND RELATED PARTS
5-8. Removal of Related Parts-Housing Assembly,
avoid personal injury while removing
7537556
the dial.
Warning:
a.
spring loaded, use precaution to
5-1