Table 4-18.1. Operational Program Loading Using Tape Reader, Part No. 877406-2 -- Continued
Malfunction
indication/corrective action
Normal indication
Test procedure
No. 10 LED indicator lights steady
j. Lift tape reader read head cover
and install PADS operational pro-
gram tape number 877419-X on
tape reader. Do not tape program
tape to take-up reel. Manually ad-
vance tape beyond readable tape
leader. Gently lower read head
cover
k. Turn on + 28V power source
l. Set PS BATTERY and VEHICLE
breakers CB1 and CB2 to ON
PADS ON switch-indicator lights
m. Press PADS ON/OFF switch-in-
dicator to on
PARITY ERROR indicator may light
n. Press EXECUTE switch-indicator
to on
o. S e t tape r e a d e r SPL/LOOP
switch to SPL
MEMORY LOAD switch-indicator
p. Press EXECUTE switch-indicator
t o off and press MEMORY
lights
LOAD switch-indicator to on
Tape reader reads first tape section
and stops in less than 1 minute
NOTE
Press MEMORY LOAD switch-indi-
cator off and back on if a stop code
is reached prior to tape data being
loaded.
MEMORY LOAD switch-indicator
q. Press MEMORY LOAD switch-
indicator to off
goes off
VERIFY switch-indicator lights
r. Press VERIFY switch-indicator to
VERIFY ERROR switch-indicator
on
lights and tape stops: Refer to 2h
Tape reader reads second section of
tape and stops at end
NOTE
Press VERIFY switch-indicator off
and back on if a stop code is reached
prior to tape data being loaded.
VERIFY switch-indicator goes off
s. Press VERIFY switch-indicator to
off
t. Press EXECUTE switch-indicator
EXECUTE switch-indicator lights
to on
4-106.3