TM5-6675-296-14
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Microscope
eyepiece defective.
Remove eyepiece by turning counterclockwise. Replete eyepiece.
4. LIGHTS ON VERTICAL AND HORIZONTAL CIRCLES UNEQUAL OR ABSENT
Step 1. Horizontal circle or verticle illuminating mirror defective.
Remove mirrors by pulling output with a twisting motion.
Replace mirrors.
Step 2. Lamp fitting defective.
Replace fitting.
5. TRIPOD LEGS WILL NOT LOCK IN POSITION
Leg clamping Screws defective or missing.
Replace screws.
6. LEVELING SCREWS TOO TIGHT OR TOO LOOSE
Clean and lubricate the screws.
7. AUTOCOLLIMATING EYEPIECE FAILS TO ILLUMINATE (Model T2-46-C-MIL)
Step 1. Connections loose.
Tighten connections.
Step 2. Eyepiece defective.
Replace eyepiece.