TM5-6675-296-14
(3) Inspect the gasket in the carrying case
CAUTION
Do not grasp the left hand axle bearing
when lifting the theodolite. This will cause
make readjustment necessary.
TS 6675-296-14/4-3
(4) Inspect the carrying case desiccant for
or missing parts, cracked or scratched lens and
discoloration.
mirrors, loose or missing hardware, and other
indications of damage.
NOTE
Desiccant should be blue in color. Pink desiccant in-
dicates moisture saturation and must be dehydrated or
for rough travel and instability throughout their
replaced. Instrument should be inspected for moisture
range. The leveling screws must turn easily with
damage if desiccant is pink.
thumb and finger pressure, but they must be tight
c. Theodolite.
enough to hold the instrument in any position.
(1) Visually inspect the theodolite for broken
Leave screws at midpoint of travel.