TM5-6675-296-14
NOTE: THEODOLITE MODEL
T2 - 68MIL SHOWN
REMOVE ALL MODELS
IN A SIMILAR MANNER.
STEP 1.
LOOSEN THE THREE NUTS AND PULL LEVERS AWAY FROM CARRYING CASE BASE.
STEP 2.
GRASP THE RIGHT-SIDE AXLE BEARING WITH ONE HAND AND PLACE THE OTHER HAND BELOW
THE HOUSING; LIFT THE THEODOLITE FROM THE CARRYING CASE BASE.
STEP 3.
PLACE THE THEODOLITE ON A FIRM, LEVEL SURFACE.
TS 6675-296-14/4-2
Figure 4-2. Theodolite carrying
case base, removal and installation.