TM 5-1260-206-34
TID Troubleshooting Procedures
Table 7-2.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
POWER INDICATOR NOT LIT.
Check that fuse F1 on lamp control assembly is good.
Step 1.
If good, do step 2.
If bad, replace fuse.
Rotate left and right lamp dimmers fully clockwise. Using
Step 2.
multimeter, check P1 between pin B and pin D or between
pin A and pin E for approximately 750 volts ac.
If voltage is present, replace power indicator.
connector, fuseholder, power ON/OFF switch or inter-
Check that malfunction is corrected.
Step 3.
If not, refer faulty TID to depot maintenance
personnel.
2.
ILLUMINATORS NOT LIT.
Check that TID power indicator is lit.
Step 1.
I f lit, do step 2.
If not lit, refer to item 1 above.
Rotate left and right lamp dimmers fully clockwise. Using
Step 2.
multimeter, check P1 between pin B and pin D for right
illuminator and between pin A and pin E for left
i l l u m i n a t o r . Approximately 750 volts ac should be present.
If voltage is present at both pins, refer to
f a u l t y wire, connector, or illuminator. Replace
If voltage is not present at one pin, refer to
7-3