TM5-1260-206-34
Table 2-1.0.
APPS System Fine Alignment Procedures - Continued
STEP ITEM
NO.
PROCEDURE
X Display
Rotate adjust
indication
Observe
Adjust
screw (14)
Zero system. (See step 11.)
e.
Changes from 0.062 to
f.
Clockwise
R34
0.063
(R65)
Alignment Meter
Counter-
g.
High-to-low
clockwise
transition on
center grid
line
Zero system. (See step 11.)
h.
Adjustments interact.
Repeat steps a. through f. as necessary.
i.
Perform X-Y Plot diagnostic. (See table 2-5.) If X STD is
j.
out of tolerance, repeat steps 7 through 12 using a different
zero reference point.
ALIGNMENT KIT REMOVAL
13
Precision alignment assembly (7)
The precision alignment assembly is
a delicate instrument. Handle with
care.
2-39