TM5-1260-206-34
Table 2-10.
APPS System Fine Aligmnent Procedures - Continued
STEP ITEM
NO.
PROCEDURE
2
Block (2).
Install by doing the following:
a. Move photo-carriage to front of base plate.
Position guide on cursor coil mounting bracket.
b.
Secure with
two knurled screws.
Guide bar (3).
3
Install by doing the following:
a.
Remove nine screws (4) from base plate.
Remove Y-axis stop
bar (5) from base plate.
Insure clamp (6) is in end position.
b.
c. Pull spring loaded block (2) to accommodate guide bar. Place
guide bar in block to contact three rollers. Position clamps
(6 and 7) on right and left edges of base plate. Do not
tighten clamps.
4
Precision alignment assembly (8).
The precision alignment assembly is a
Install by doing the following:
Insert assembly clamps (9) into slots on left side of base
a.
plate. Tighten clamp screws (10).
Move photo-carriage (13) until meter rod (11) and push rod (12)
b.
align with bar (l). Tighten guide bar clamps (6) and (7).
2-34