TM5-1260-206-34
Table 2-10.
APPS System Fine Alignment Procedures - Continued
STEP
ITEM
PROCEDURE
NO.
Guide bar (3)
5
Align by doing the following:
Digital Display Indication
Action
a. Apply power to APPS.
Keep slight pressure against
Move photo-carriage to left.
b.
guide bar.
x
Y
c. Press:
0.000
0.000
Y
x
Move photo-carriage to
d.
0.000
counts
right. Keep slight
--0.003
+
pressure against guide
bar.
Y
If required indication
e.
0.000
is not obtained, loosen
guide bar clamps (6) and
(7) and reposition guide
bar. Tighten clamps.
Repeat steps b. through e. as necessary until no adjustment
f.
is required.
Preliminary settings:
6
Do the following:
a. Hold tip of meter rod (2) with
finger. Slide lock lever (1)
to edge. Slowly release meter
rod until it contacts bar.
Remove spring (3). Reconnect
b.
to bar post (4) then to pre-
cision alignment assembly post
(5) .
Photo-carriage (13)
7
Using push rod adjusting screw (14) move photo-carriage near center
of base plate.