Figure 11. Terminal box (inside).
c. Drill or cut a 1.375 0.03 inch diameter hole to
NOTE
First, it may be necessary to remove
be located on the control console (fig. 10). Weld pipe
either a square metal tray (for magnetic
compass mounting) or a pair of metal
brackets (for mark 27 gyro compass
12. lndicator Mounting Preparation
mounting) to clear the area.
With
a.
Place indicator mounting plate (10, fig. 14) on
indicator mounting plate in centralized
control console and position so that plate is centralized
position, use a template and locate and
among the instrument cluster. If indicator mounting
drill the 12 mounting holes. Locate and
plate interferes with any of the installed instruments and
cut the 5-inch square cutout. See figure
will not lie flat on panel, trim plate as required to fit.
13.
14