TM 55-1905-223-24-14
2-20. Replace Bearing Repeater. (FIGURES 2-12 and 2-13)
This task covers: a. Removal, b. Replacement.
INITIAL SETUP
Tools
General Instructions
Tool kit, general mechanic's,
port bridge wing, (2) starboard bridge
Tool kit, electrician's,
wing and (3) top of pilothouse. Trans-
mission power to each bearing repeater
is controlled by switches in relay
Materials/Parts
S1 (port bridge wing), S5 (starboard
Bearing repeater, P/N 1976158-3
bridge wing), and S7 (top of pilot-
Thread compound, (Appendix C, Item 3)
house).
Warning tags, Appendix C, Item 8
REMOVAL
a. On relay, transmitter (1, FIGURE 2-12), loosen four retaining clips (2) and open cabinet cover (3).
WARNING
Ship's ac power is present at FUSE F1 and POWER switch S1 terminals on the inside of the cabinet
cover. THESE VOLTAGES ARE DANGEROUS. Use extreme care when working inside of cabinet.
b. On A2 circuit card assembly (4) set appropriate repeater switch (5) to the down position and close cover (3).
Secure four retaining clips (2).
c.
d. On appropriate pelorus stand (4, FIGURE 2-13) loosen two pivot nuts (12) pivot screws (11) on support plate (3).
e. Rotate bearing repeater (2) on pivot screws to BOTTOM VIEW position. Secure pivot nuts (12), holding bearing
repeater (2-) in this position.
f.
Remove eight screws (6), lockwashers (7), and flat washers (8) from cover (9).
2-47