TM 55-1905-223-24-14
(10) Loosen two bolts (1) on mounting bracket arms (2) and rotate repeater (3) to desired viewing position.
(11) Secure repeater (3) by securing two bolts (1).
(12) Start compass (TM 55-1905-223-10).
(13) Verify operation of lamps.
b. Special purpose electrical cable (6 ft) replacement. (FIGURE 2-11).
(1)
On bulkhead mounting bracket arms (8), loosen two mounting bolts (1) and rotate open scale repeater (9)
to ROTATED position and secure mounting bolts (1).
(2)
Remove eight screws (14), lockwashers (13), and flat washers (12) from cover (11).
(3)
Remove cover (11) from open scale repeater (9) as far as cabling will allow.
(4)
Tag and disconnect cable (5) wiring from terminal board (10).
(5)
Disassemble stuffing tube (2) from cable (5) and pull cable (5) from open scale repeater (9).
(6)
On bulkhead mounting bracket cover (6), remove six screws (3) and washers (4) and remove cover (6) as
far as cabling inside will allow.
(7)
Tag and disconnect cable (5) wiring from terminal board (7) inside of junction box.
(8)
Disconnect cable (5) connector from junction box and connector adapter pull cable (5) from junction box.
(9)
Route replacement cable (5) into junction box through junction box connector adapter. Secure connector
to connector adapter.
(10) Connect cable ('5) wiring to junction box terminal board (7). Remove tags.
(11) Dress cable (5) wiring inside of junction box and position cover (6) and secure with six washers (4) and
screws (3).
(12) Assemble cable (5) and stuffing tube (2) into open scale repeater (9) cover (11).
(13) Connect cable (5) wiring to open scale repeater (9) terminal board (10). Remove tags.
(14) Secure stuffing tube (2) and dress cable (5) wiring inside of open scale repeater (9).
2-44