TM 55-1905-223-24-14
l.
Set repeater switches A2S1 through A2S8 to ON.
rn. Close cabinet door and secure four fasteners (2, Sheet 1) by securing four pan head screws (12).
n. Connect ground cable (6) to ground terminal (5) and secure with lockwasher (7) and hex nut (8).
o. On pilothouse PANEL, set circuit breaker No. 4 (MK 27 HEADING XMTR) to ON. Remove "Out of Service, Do
Not Operate" tag.
p. On relay transmitter (1), set POWER OFF switch (4) to up position. POWER lamp should light red.
q. Start compass (TM 55-1905-223-10).