ARMY TM 5-6675-308-34
MARINE CORPS TM 08837A-34/2
Table 4-14.1 IMU Testing,
Alignment, and Troubleshooting Using Tape Reader, Part No.
877406-2
Continued
`Malfunction
indication/corrective action
Normal indication
Test procedure
SELECT TEST MODE
Checksum is incorrect Refer to step 3k
Checksums are equal
2b. Compare printed checksum
written on the front of the
punched tape in use
2c. Type IMU to select IMU auto- TTY prints out:
NOTE
matic alignment and test se- IMU
From this step forward, the TTY
quence
may print out any of the malfunction
SER NO XXXX
DATE XXXX
the corrective action shown in table
CHECKSUM XXXXXX
MOVE IMU TO APPROX 45 DEC
HEADING
WHEN DONE TYPE: RDY
Data matches
Reload IMU alignment data tape
2d. Verify that the printed serial
number matches the' serial num-
her of the IMU under test and
t h e checksum matches the
checksum on the IMU alignment
data tape
NOTE
2e. Type RDY when 45 (10) TTY prints out:
heading request has been com- RDY
The program will accept all data on
pleted
one line, thus if the operator makes
a mistake prior to typing RDY while
(SEC) RDY
entering data via the TN, he should
hit the carriage return key and reen-
ter the data. If the diagnostic pro-
gram does not recognize the entry as
valid, the TTY prints out: IM-
PROPER DATA ENTRY. The oper-
ator should reenter the data.