ARMY TM 5-6675-308-34
MARINE CORPS TM 08837A-34/2
Table 4-10. Computer
Automatic Test Mode
Malfunction Teletypewriter Messages
Teletypewriter malfunction message
Corrective action
NOTE
Replace cards in sequence given
16-bit data circuit card assembly A2
Absence of XXX TEST CYCLES PASS
message at approximately 2-minute intervals
Control no. 2 circuit card assembly A4
or CPU OP-CODE TEST FAIL
Control no. 3 circuit card assembly A5
Control no. 1 circuit card assembly A3
Memory unit Al
Reseat memory unit Al and check wedgelocks
MEMORY TEST FAIL
for tightness
Memory unit Al
16-bit data circuit card assembly A2
Control no. 2 circuit card assembly A4
Control no. 3 circuit card assembly AS
I/O controller card assembly A7
Data buffer circuit card assembly A6
I/O controller card assembly A7
PRIORITY INTERRUPT TEST FAIL
Data buffer circuit card assembly A6
I/O discrete circuit card assembly A9
Control no. 3 circuit card assembly A5
I/O controller card assembly A7
SERVICE INTERRUPT TEST FAIL
Data buffer circuit card assembly A6
Control no. 3 circuit card assembly ASI
I/O discrete circuit card assembly A9
DISCRETE I/O TEST FAIL
Data buffer circuit card assembly A6
I/O controller card assembly A7
Computer power supply PS1
Platform I/O circuit card assembly A8
PLATFORM I/O TEST FAIL
Change 1