ARMY TM 5-6675-308-34
MARINE CORPS TM 08837A-34/2
Table 4-9. PADS Diagnostic/Alignment Program Malfunction Words - Continued
Bit Location
Malfunction
9
10
11
12
13
14
15
BPFAIL (PLAT I/O TEST)
0
Test incomplete at IMU ready
1
DVZ fail to count (inactive)
2
DVY fail to count (inactive)
DVX fail to count (inactive)
3
4
DVZ fail to reset on read
5
DVY fail to reset on read
DVX fail to reset on read
6
DWZ 3 MSB count down error
7
DWY 3 MSB count down error
8
DWX 3 MSB count down error
9
10
DVZ count up/down error
11
DVY count up/down error
DVX count up/down error
12
13
DWZ/DVZ error long loop SPU
DWY/DVY error long loop SPU
14
15
DWX/DVX error long loop SPU
BIFAIL T (IMU TEMPERATURE TEST)
0
Ambient temp. time between 110, 120 G.T. 1.5 min
1
Ambient too low LT 30 at 5 min or LT 120 at 20 min
2
Ambient too high GT 126 at 20 min
3
Ambient overheat was below 126 now GT 140
4
Upper gyro temp too low LT 150
5
Upper gyro temp too high GT 160
6
Lower gyro temp too low LT 150
7
Lower gyro temp too high GT 160
8
9
10
11
12
13
14
15
4-64