ARMY TM 6-6675-308-34
MARINE CORPS TM 08837A-34/2
Table 4-6.3. Solid State Memory Loading Using Tape Reader, Part No. 877406 -2- Continued
Malfunction
indication/corrective action
Normal indication
Test procedure
2c. Set tape reader FAST/SLOW
switch to FAST
REVERSE switch-indicator lights. Tape
2d Press REVERSE switch-in-
rewinds and stops at beginning of
dicator to on
reel
REVERSE switch-indicator goes off
2c. Press REVERSE switch-in-
dicator to off
NOTE
Tape will stop near the beginningof
the reel. Repeat steps 2d and 2e
until tape stops at end of readable
leader.
No. 10 LED indicator lights steady
2f. Lift tape reader read head cover
and remove part 1 and load part
2 (of 3) of PADS solid state pro-
gram 868182-X on tape reader.
Gently lower read head cover.
2g. Set tape reader FAST/SLOW
switch to SLOW
MEMORY LOAD switch-indicator
2h. Press MEMORY LOAD switch-
indicator to on
lights. Tape reader reads tape and
stops at end of reel
2i. Press MEMORY LOAD switch-
MEMORY LOAD switch-indicator
indicator to off
goes off
2j. Set tape reader FAST/SLOW
switch to FAST
REVERSE switch-indicator lights.
2k. Press REVERSE switch-indica-
Tape rewinds and stops at beginning
tor to on
of reel
2f. Press REVERSE switch-in-
REVERSE switch-indicator goes off
dicator to off
2m. Lift tape reader read head cover
No. 10 LED indicator lights steady
and remove part 2 and load part
3 (of 3) of PADS solid state
program tape number 868182-X
on tape reader. Gently lower
read head cover
2n. Set tape reader FAST/SLOW
switch to SLOW
2o. Press MEMORY LOAD switch-
MEMORY LOAD switch-indicator
indicator to on
lights. Tape reader reads tape and
stops at end of reel
2p. Press MEMORY LOAD switch-
MEMORY LOAD switch-indicator
goes off
indicator to off
2q. Set tape reader FAST/SLOW
switch to FAST
4-54.16
Change 6