ARMY TM 5-6675-308-12
MARINE CORPS TM 08837A-12/1A
Table 12. Characteristics and Performance Data
Value
Item
Power Requirements:
961 watts (40.0 amp at 24 VDC)
Steady state load
2338 watts (97.4 amp at 24 VDC)
Transient (warmup) load
Up to 7 hours
Total Mission Duration:
+75N to 75S
Latitude Limits:
Within a circle with radius of
Survey Area
55 kilometers from the last
update point
Surveying Accuracy:
(10 Min. Zero Velocity Correction)
Battalion Survey Operations
0-65 North/South
6575 North/South
10.0
7.0
Horizontal Position (Meters CEP)
3.0
3.0
Vertical Position (Meters PE)
0.4
Azimuth (Mils PE)
0.6
(5 Min. Zero Velocity Correction)
DIVARTY Survey Operations
0-65 North/South
6575 North/South
4.0
7.0
Horizontal Position (Meters CEP)
2.0
2.0
Vertical Position (Meters PE)
Azimuth (Mils PE)
0.4
0.6