TM5-6675-296-14
MALFUNCTION
STEP 1.
UNLOCK THE HORIZONTAL CLAMP. ROTATE THE U-STANDARD UNTIL THE PLATE LEVEL IS
PARALLEL TO A LiNE JOINING ANY TWO LEVELING SCREWS. LOCK THE CLAMP.
TURN THE TWO LEVELING SCREWS THAT ARE PARALLEL WITH THE PLATE LEVEL.
STEP 2.
SIMULATANEOUSLY, BUT IN OPPOSITE DIRECTIONS UNTIL THE LEVEL BUBBLE IS
CENTERED.
UNLOCK THE HORIZONTAL CLAMP. ROTATE THE U-STANDARD 90O AND LOCK THE CLAMP.
STEP 3.
TURN THE THIRD LEVELING SCREW UNTIL THE LEVEL BUBBLE CENTERED.
UNLOCK THE HORIZONTAL CLAMP. ROTATE THE U-STANDARD 180 AND LOCK THE CLAMP.
STEP 4.
TURN THE SAME LEVELING SCREW AS IN STEP 3 AND REMOVE ONE-HALF OF ANY BUBBLE
DISPLACEMENT THAT MAY EXIST.
IF AFTER STEP 4 THE PLATE LEVEL BUBBLE IS MORE THAN TWO DIVISIONS FROM
NOTE:
CENTRALITY, THE CORRECTION IS MADE WITH THE PLATE LEVEL ADJUSTING SCREW.
TS 6675-296-12/3-2