TM5-6675-296-14
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
NOTE: THEODOLITE MODEL
T2 - 68MIL SHOWN
INSTALL ALL MODELS
IN A SIMILAR MANNER.
POSITION THEODOLITE ON TRIPOD HEAD AND SECURE LOOSELY WITH BRIDGE SCREW.
STEP 1.
STEP 2.
CENTER CIRCULAR LEVEL BUBBLE USING LEVELING SCREWS.
STEP 3.
SIGHT THROUGH OPTICAL PLUMMET EYEPIECE AND ADJUST EYEPIECE UNTIL THE
CIRCULAR MARKS ARE CLEARLY VISIBLE.
STEP 4.
CAREFULLY MOVE THEODOLITE ON TRIPOD HEAD UNTIL THE STATION POINT IS
CENTERED ON THE EYEPIECE CIRCULAR MARKS.
STEP 5.
T I G H T E N BRIDGE SCREW.
TS 6675-296-14/3-1