TM 5-1260-206-12
Table 3-2.
Troubleshooting Procedures - Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
OMS - Continued
7.
Impaired Image of Photography
Do PMCS item no. 3 thru 8.
If malfunction is not corrected, refer faulty OMS
to DS/GS maintenance personnel.
TID
8.
Illuminators Do Not Light
Step 1.
Check whether both illuminators do not light.
If both, do step 2.
I f one, replace illuminator.
Step 2.
Check that power indicator on lamp control assembly is
lit.
I f lit, replace illuminator.
If out, do step 3.
Step 3.
Check that fuse F1 on lamp control assembly is good by
replacing with known good fuse.
no. 5.)
If good, refer faulty TID to DS/GS maintenance personnel.
I f bad, replace fuse.
Step 4.
Check that malfunction is corrected.
If not, refer faulty TID to DS/GS maintenance personnel.
CALCULATOR
Does Not Appear On Display
9.
Check that calculator fuse is good by replacing with known good fuse.
If good, refer faulty calculator to DS/GS maintenance
personnel.
I f bad, replace fuse.
3-5