TM 11-4920-292-15
P1-46 and J1-46
Electrical Special Purpose Cable
P1-48 and J1-48
Assembly CX-10934/ASN Test
P1-49 and J1-49
P1-50 and J1-50
and alligator clips using multimeter. Continuity
P1-51 and J1-51
shall exist between the following pins and
P1-54 and J1-54
clips:
P1-55 and J1-55
P1-A and WHT
J1-42 and P2-B
P1-B and BLU
J1-43 and P2-C
P1-C and YEL
J1-44 and P2-A
P1-D and RED
J1-11 and P2-F
P1-E and BLK
b. Measure insulation resistance between
P1-F and GRN
connector pins and between each connector pin
b. Measure insulation resistance between
and connector shells J1, P1, P2, and P3 using
connector pins and between each connector pin
ohmmeter. With 250 volts dc applied, insulation
and connector shell P1 using ohmmeter. With
resistance shall be 20 megohms or more.
250 volts dc applied, insulation resistance shall
be 20 megohms or more.
11-23. Electrical Special Purpose Cable
Assembly CX-10936/ASN Test
11-22. Branched Electrical Special
a. Measure resistance between connector
Purpose Cable Assembly CX-
10935/ASN Test
between the following pins:
a. Measure resistance between connector
J1-A and P1-A
J1-B and P1-B
between the following pins:
J1-C and P1-C
P1-1 and J1-1
J1-D and P1-D
P1-1 and J1-1
J1-E and P1-E
P1-2 and J1-2
J1-F and P1-F
P1-3 and J1-3
b. Measure insulation resistance between
P1-4 and J1-4
connector pins and between each connector pin
P1-5 and J1-5
and connector shell J1 using ohmmeter. With
P1-6 and J1-6
250 volts dc applied, insulation resistance shall
P1-7 and J1-7
be 20 megohmsor more.
P1-8 and J1-8
P1-9 and J1-9
11-24. Branched Electrical Special
P1-10 and J1-10
Purpose Cable Assembly
P1-11 and J1-11
CX-10937/ASN Test
P1-12 and J1-12
P1-13 and P3-A
P1-14 and P3-B
P1-15 and P3-C
tween the following pins:
P1-16 and P8-D
J1-F and P1-F
P1-17 and P3-E
J1-E and P1-E
P1-28 and J1-28
J1-D and P1-D
P1-35 and J1-35
J1-F and P2-F
P1-42 and P2-H
J1-E and P2-K
P1-43 and P2-J
J1-D and P2-L
P1-44 and P2-G
J1-A and P2-G
J1-B and P2-H
P1-45 and J1-45