ARMY TM 5-6675-308-34
MARINE CORPS TM 08837A-34/2
Table 4-18. Operational Program Loading -- Continued
Malfunction
indication/corrective action
Test procedure
Normal indication
j. Install PADS operational program
tape number 877419-X on tape
reader. Do not tape program tape
to take-up reel. Manually advance
tape beyond readable tape leader
k. Turn on + 28V power source
l. Set PS BATTERY and VEHICLE
breakers CB1 and CB2 to ON
m. Press PADS ON/OFF switch-in- PADS ON switch-indicator lights
dicator to on
PARITY ERROR indicator may illu-
minate
m.1. Press EXECUTE switch-indi-
cator to on
n. Set tape r e a d e r SPOOLING
switch to ENABLE
n.1. Press EXECUTE switch-indica-
tor to off
o. Press MEMORY LOAD switch- MEMORY LOAD switch-indicator
indicator to on
lights
Tape reader reads first tape section
and stops in less than 1 minute
NOTE
Press MEMORY LOAD switch-indi-
cator off and back on if a stop code
is reached prior to tape data being
loaded.
p. Press MEMORY LOAD switch-
MEMORY LOAD switch-indicator
indicator to off
goes off
VERIFY ERROR switch-indicator
q. Press VERIFY switch-indicator to
VERIFY switch-indicator lights
lights and tape stops: Refer to 2h
on
Tape reader reads second section of
tape and stops at end
NOTE
Press VERIFY switch-indicator off
and back on if a stop code is reached
prior to tape data being loaded.
r. Press VERIFY switch-indicator to VERIFY switch-indicator goes off
off
s. Press EXECUTE switch-indicator EXECUTE switch-indicator lights
to on
4-103
Change 5