TM 5-6675-250-10
2-9. PREPARATION FOR MOVEMENT - Continued
PUTTING SIAGL BACK IN SERVICE - Continued
i.
Tighten each of the three hold-down
clamps on the tripod.
POWER CABLE INSTALLATION
a.
Connect interconnect cable (1) to the ECU
(2) and GRU (3).
Connect DC power cable (4) to the POWER
b.
receptacle (5) on ECU (2) and to a 22-23
Vdc power source.
NOTE
Auxiliary cables and an AC-DC converter
are stored in the transport case for use as
needed.
c.
Remove AC-DC converter and associated
cables from transport case.
d.
Remove protective caps (1 and 2) from
Connect the 115 Vac cable (5) between AC
e.
power source and input receptacle (3).
f.
Connect power cable (6) between output
receptacle (4) on the converter (7) and the
power receptacle on the ECU.
2-69