TM 1 1-6625-2440-12
Seq
Item
Procedure
Reference
No.
Switch
position
Voltage
+3.8 ( 1.4)
11
+3.8 ( 1.4)
12
16
Mode control .......................
Note. When the C-D CAGE switch is set to
OFF, the test set will sequence through
level, GC1, and GC2 modes. When the C-
D CAGE switch In set to OFF, the C-D
LEVEL indicator lights. Within 120 ( 12)
seconds, the C-D LEVEL indicator goes out
and the C-D GC1 indicator lights. Within
240 (-24) seconds after C-D GC1 indicator
lights, the C-D GC1 indicator goes out and
the C-D GC2 indicator lights. As soon as
each mode indicator lights, tests relating to
each mode
must be performed within the specified
time. Simultaneously start stopwatch and
set C-D CAGE switch to OFF; then perform
the following steps
a. Observe that C-D CAGE indicator goes
out and C-D LEVEL indicator lights.
b. Set EU SCAN SELECT switch to
DISCRETES.
c. Set EU TEST SET SCAN switch to
positions indicated below, and
observe scope and DVM for voltages
listed.
Switch
position
Voltage
+3.8 ( 1.4)
4
+3.8 ( 1.4)
5
+3.8 ( 1.4)
6
+0.25 ( 0.25)
8
+0.25 ( 0.25)
9
+3.8 ( 1.4)
10
+0.25 ( 0.25)
11
+3.8 ( 1.4)
12
d. Set EU SCAN SELECT switch to A.
e. Set EU PLATFORM SCAN switch to
positions indicated below, and
observe scope for voltages listed.
Switch
position
Voltage
+3.8 (1. 4)
11
+0.25 ( 0.25)
12
f. At T=120 ( 12) seconds, observe that
C-D LEVEL indicator goes out and
C-D GC1 indicator lights start
stopwatch and perform g through k
below.
g. Set EU SCAN SELECT switch to
DISCRETES.
h. Set EU TEST SET SCAN switch to
positions indicated below, and
observe scope and DVM for voltages
listed.
Switch
position
Voltage
+3.8 ( 1.4)
4
+0.26 ( 0.2)
5
+3.8 (:1.4)
8
+0.25 ( 0.25)
9
+3.8 ( 1. 4)
10
+0.25 ( 0.25)
11
+3.8 ( 1.4)
12
i. Set EU SCAN SELECT switch to A
j. Set EU PLATFORM SCAN switch to
positions indicated below, and
observe scope for voltages listed.
Switch
position
Voltage
+0.25 ( 0.25)
11
+3.8 ( 1.4)
12
k. At T-240 ( 24) seconds, observe that
C-D GC1 indicator goes out and C-D
GC2 indicator lights.
3-11