TM 55-1905-223-24-14
Table 2-3. Unit Maintenance Troubleshooting - CONT
Malfunction
Test or Inspection
Corrective Action
GYRO COMPASS SYSTEM - Continued
STEP 2. Check to see if POWER lamp is defective.
STEP 3. Check for power to gyro control and power assembly.
Check IC/ELEX power panel circuit breaker No. 1. Reset.
STEP 4. Check cables and connections for security, kinks, or breaks.
Replace cables. Refer to TM 55-1905-223-24-18.
8. Gyro compass slews when compass caged; CAGED lamp is lit.
STEP 1. Check to see if gyro compass is defective.
STEP 2. Check to see if gyro control and power assembly is defective.
9. FOLLOW-UP ALARM lamp lit, slews rapidly when TILT/AZIMUTH switch is operated.
STEP 1. Check to see if gyro control and power assembly is defective.
10. Compass fails to slew when using TILT/AZIMUTH switch; FOLLOWUP ALARM lamp
not lit.
STEP 1. Check to see if 8 AMP dc fuse is blown.
STEP 3. Check to see if gyro control and power assembly is defective.
11. FOLLOW-UP ALARM lamp lit, compass does not slew correctly when TILT/AZIMUTH
switch operated.
STEP 1. Check to see if gyro control and power assembly is defective.
12. CACED lamp does not light when compass caged.
STEP 1. Check to see if CAGED lamp is defective.
2-11