TM 55-1905-223-24-14
Table 1-1. Equipment Data - CONT
Characteristic
Reference Data
Bearing Repeater Power Input
70 Vdc step voltage
24 Vdc lamp voltage
Pelorus Stand Power Input
70 Vdc step voltage
24 Vdc lamp voltage
Open Scale Repeater Power Input
70 Vdc step voltage
24 Vdc lamp voltage
Bulkhead Mounting Bracket Power
70 Vdc step voltage
Input
24 Vdc lamp voltage
d. Safety, Care and Handling. Safety precautions must be observed at all times while performing maintenance.
General WARNINGS and first-aid data appear in front of this manual. Review all safety information before starting any
task. Carefully read through an entire maintenance procedure before performing any maintenance function. Make sure
the task can be done safely. All WARNINGS, CAUTIONS, and NOTES are of great importance to your safety and the
safety of the equipment.
(1) Keep Away From Live Circuits. The soldier must at all times observe all safety regulations. Do not
replace components inside the equipment with power turned on. Under certain conditions, dangerous potentials may exist
when power is turned off. Always remove power at its source, and discharge or ground a circuit before touching it.
(2) Do Not Service Alone. Under no circumstances should any soldier reach into or enter an enclosure
for the purpose of maintenance or service of the equipment except in the presence of another soldier who is capable of
rendering aid and assistance.
(3) Resuscitation. Soldiers working with or near energized equipment should be familiar with modern
1-7. Magnetic Compass.
a. Equipment Characteristics, Capabilities, and Features. These are broad points about the magnetic compass.
(1) Characteristics:
o Magnets align themselves with the magnetic field in which they exist.
1-23