Table 4-2. Troubleshooting
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
THEODOLITE AND TRIBRACH ASSEMBLY
1.
THEODOLITE AND TRIBRACH ASSEMBLY WILL NOT SEAT PROPERLY ON TRIPOD HEAD
Step 1. Check alinement of the central fixing screw.
Step 2. Inspect tribrach assembly for defects.
Replace defective tribrach assembly (see fig. 2-1).
Step 3. Tripod head defective.
Replace tripod.
2. THEODOLITE AND TRIBRACH ASSEMBLY WILL NOT STAY ON LINE
Step 1. Check theodolite and tribrach assembly leveling (fig. 2-21).
Replace theodolite and tribrach assembly.
3. LIGHTS ON VERTICAL AND HORIZONTAL CIRCLES UNEQUAL OR ABSENT
Step 1. Plug-in lamp defective.
Step 2. Batteries defective.
Step 3. Illuminating mirror defective.
Replace theodolite.
4. TRIPOD LEG WILL NOT LOCK IN POSITION
Leg clamping screws loose.