TM 5-6675-312-14
2-7. INITIAL ADJUSTMENTS AND DAILY CHECKS
a. General. Perform the daily preventive maintenance services (para. 2-4).
b. Metal Carrying Case.
(1) Inspect the metal carrying case hood and base (fig. 2-7) for dents, cracks, and rust. Inspect clamps and
carrying strap for defects.
(2) Inspect the gasket in the metal carrying base (fig. 2-8).
(3) Inspect the metal carrying case desiccant for discoloration.
NOTE
Desiccant should be blue in color. Pink desiccant indicates moisture saturation and must be
dehydrated or replaced.
c. Theodolite and Tribrach assembly.
(1) Visually inspect the theodolite for broken or missing parts, cracked or scratched lenses and mirror, loose
or missing hardware, and other indications of damage.
(2) Rotate the tribrach assembly three footscrew assemblies (fig.
2-1) and inspect for rough travel and
instability.
(3) Inspect the theodolite horizontal drive screw and horizontal clamp (fig. 2-1) for proper operation.
(4) Inspect the theodolite vertical drive screw and vertical clamp (fig. 2-1) fo r proper operation.
(5) Inspect the theodolite telescope eyepiece, reading microscope eyepiece, and focusing sleeve (fig. 2-1) for
proper operation and smooth operation throughout their full travel.
d. Tripod.
(1) Refer to figure 2-11 and inspect the tripod for damaged or missing parts and loose or missing hardware.
(2) Refer to figure 2-12 and inspect the tripod accessory case for damage. See that the plumbbob assembly
and allen wrench are contained in the case and are in serviceable condition.
2-21