TM 5-6675-306-14
16.
Cover plate spring
WARNING
1. Insulation plate
17.
Wood screw (3)
2. Rivet (2)
18.
Contact
Dry cleaning solvent, P-D-680, used to
3. Contact plate
19.
Cover plate knob
clean parts is potentially dangerous to
4. Contact spring 12)
20.
Cover plate
personnel and property. Avoid repeated
5. Nut (21
21
Wood block
and prolonged skin contact. Do not use
6. Rheostat
22
Contact plate
near open flame or excessive heat.
7. Cable clip
23.
Nut
Flash point of solvent is 10 F.-138
8. Spring
24
Wood screw (31
F. (38 C.-59 C.)
9. Machine screw
25
Battery case
(1) Clean all metal parts with an approved cleaning
10 Electric cable
26
Setscrew
solvent and dry thoroughly.
11. Insulation tube
27
Rheostat knob
12. Screw (2)
28.
Pin
13 Electric plug (2)
29
Washer
(2) Inspect the lamps for defects. Inspect all
14. Dummy battery (2)
30
Carrying strap
electrical contacts for breaks, wear, and corrosion.
15. Bulb, 2.5V (4)
31
Screw 121
(3) Inspect insulation for cracks, wear, and damage.
Inspect the electrical cable for breaks and frayed
7-3.
Handlamp and Connecting Cable
insulation. Inspect the cable connectors for breaks and
defective terminals.
a. General. The handlamp is used for general
external lighting purposes. The connecting cable is
(4) Inspect the housing and body for dents, rust,
used to provide power from the battery box to the
burrs, and other defects.
handlamp.
When not in use the handlamp and
connecting cable are stores in the battery box.
(5) Remove all burrs and straighten dents. Replace
all defective parts that cannot be repaired.
b. Disassembly.
and
disassemble the handlamp and connecting cable.
d. Reassembly.
and
reassemble the handlamp and connecting cable.
c. Cleaning, inspection, and repair.
7-3