TM 5-1260-206-34
Table 6-2.
Digital Display Troubleshooting Procedures
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
READ-OUT NOT LIT
Step 1.
Check for continuity between plug P1, pin 20 and plug P5-r.
If good replace faulty printed circuit board.
If bad replace faulty cable.
Step 2.
Check that malfunction is corrected.
If not, refer faulty Digital Display to depot
maintenance personnel.
2.
SIGN OR NUMBER DOES NOT LIGHT
Check for continuity between plug P1 or P2 and plug P5.
Step 1.
If good, do step 2.
If bad, replace faulty cable.
Exchange unlit sign or number with known good module.
Step 2.
If sign or number lights, replace faulty module.
If sign or number does not light, replace printed
Check that malfunction is corrected.
Step 3.
If not, refer Digital Display to depot maintenance
personnel.
6-2