ARMY TM 5-6675-308-34
MARINE CORPS TM 08837A-34/2
PADS DIAGNOSTIC ALIGNMENT PROGRAM
OR
PADS SOLID STATE DIAGNOSTIC ALIGNMENT PROGRAM
PROGRAM CHECKSUM XXXXXX
SELECT TEST MODE
IMUIMU
SER NO 0002 DATE 7312 CHECKSUM 003256
MOVE IMU TO APPROX 45 DEG HEADING
WHEN DONE TYPE: RDY
RDYRDY
38 44 24.6NRDYRDY
ENTER ELEVATION: (FT)RDY
52.5RDYRDY
ENTER DATE: (JULIAN) RDY
7314RDYRDY
ENTER SER NO: (DIGITS)RDY
0002RDYRDY
ALIGNMENT PROCEEDING
IF THEODOLITE WILL NOT BE USED, TYPE: BYP
TEST NUMBER 1 IN PROGRESS
000000 000000
PULSES/SEC
1001
-1.152
OK
1002
4.004
OK
PULSES/SEC
1003
-0.027
OK
PULSES/SEC
1004
PULSES/SEC
55.879
OK
-76.180
OK
1005
PULSES/SEC
1006
-11.230
OK
PULSES/SEC
1007
PULSES/SEC
-82.195
OK
1008
PULSES/SEC
58.992
OK
PULSES/SEC
1009
-13.352
OK
000000 000000
TEST NUMBER 2 IN PROGRESS STARTED 1 MINUTE AGO
000000 000000
THEODOLITE TEST
(TO ABORT AT ANY TIME TYPE: BYP)
MOVE IMU TO 0 DEGREES PITCH 0 DEGREES ROLL
WHEN DONE TYPE: RDY
ALIGNMENT HALTED
RDYRDY
ENTER THEODOLITE READING: (MILS) RDY
ALIGNMENT HALTED
2865.00RDYRDY
-0.0624 DEGREES PITCH 10-SEC AVRGE
-0.4487 DEGREES ROLL 10-SEC AVRGE
44.3051 DEGREES AZ 10-SEC AVRGE
Change 5