TM 32-5865-O10-24&P
To replace a rivet(s) on the unit, proceed as
5-11b. Riveting.
follows:
(1) Remove covers and components as required to gain access to
rivet(s) to be replaced.
(2) Center punch the rivet head of rivet to be replaced.
(3) Using a drill smaller than the diameter of the rivet, drill
out the center of rivet head to be replaced.
(4) Increase the size of the drill to rivet size or a size
slightly smaller than rivet size, and again drill out rivet
head. Rivet head should fall off at this point. If not,
position a punch or similar tool against the rivet head and
carefully drive it out with a hammer.
(5) Using a punch and a hammer, punch out the remainder of the
rivet to be replaced.
(6) Obtain and install appropriate size rivet. Using the
riveter and appropriate size head, install the replacement
rivet.
5-11c. Fasteners. To replace a fastener (2), in the top or bottom
access cover, proceed as follows:
(1) Remove cover to be repaired. (Refer to chapter 5, section
IV.)
(2) Use small needle-nose pliers to remove split-ring washer.
(3) Remove damaged fastener.
(4) Insert new fastener through hole in cover and press on
split-ring washer.
(5) Replace cover in accordance with chapter 5, section IV.
GENERAL SUPPORT TESTING PROCEDURES
Section V.
Introduction.
This section contains performance test procedures required to
verify proper operation of the DF control/indicator. These procedures
should be performed after accomplishing a repair, or prior to system
installation.