TM 32-5865-010-24&P
Adequate ventilation should be provided while
Prolonged
using trichlorotrifluoroethane.
The
breathing of vapor should be avoided.
solvent should not be used near heat or open
flame; the products of decomposition are toxic
and irritating.
Since trichlorotrifluoroethane
dissolves natural oils, prolonged contact with
skin should be avoided. When necessary, use
gloves (item 3, App. D) that the solvent cannot
penetrate.
If the solvent is taken internally,
consult a physician immediately.
(3) Remove grease and\or ground-in dirt with a cloth dampened
(not wet) with trichlorotrifluoroethane (item 5, App. D).
Removal and Replacement.
5-10.
a. Top and Bottom Cover_Removal and Replacement. To remove top
or bottom cover (1) (figure 5-2) of the unit, loosen the four fasten-
To replace covers, posi-
ers (2) securing covers and remove covers.
tion the covers over the top or bottom of the unit and secure to the
unit with the four fasteners.
b. Rear Panel Removal and Replacement.
To remove the rear panels
(3) from the unit, proceed as follows:
(1) Remove six screws (4) and washers (5) that secure rear
panel to unit.
(2) Remove from each, four screws (8), flat washers (9), lock-
washers (10) and nuts (11) that secure connectors ,J1 and
J2 (6 and 7), then remove rear panel.
(3) To replace rear panel (3), secure connectors J1 and J2 to
panel with four screws (8), flat washers (9), lockwashers
(10) and nuts (11), then secure rear panel to unit with six
screws (4) and washers (5) .
NOTE
Two size sockets are utilized in connectors J1
For number
and J2 of the DF Control Indicator.
20 sockets, use tool number MS27495A20 for
For
insertion and MS27495R20 for socket removal.
number 22D sockets, use total number MS27495A22M
for insertion of sockets and MS27495R22M for
These insertion/extraction
socket removal.
tools are part of MK-1961/G tool kit.